Articles & Insights
Stay informed with our latest articles, tips, and industry insights on refrigeration and lubrication.
Life After R-22: A Lubricant Strategy for HCFC Phase-Out Retrofits
R-22 is being phased out, but thousands of R-22 systems are still running across Southern Africa. A lubrication engineer's guide to keeping them healt...
R-22 is being phased out, but thousands of R-22 systems are still running across Southern Africa. A lubrication engineer's guide to keeping them healthy, choosing a retrofit refrigerant, and changing oil without leaving an immiscible residue behind.
Oil Management in Screw Compressors: Separation, Cooling and Oil Analysis
In an oil-injected screw compressor, oil seals the rotors, carries away heat of compression and lubricates the bearings. How the oil circuit works, wh...
In an oil-injected screw compressor, oil seals the rotors, carries away heat of compression and lubricates the bearings. How the oil circuit works, where it goes wrong, and how oil analysis turns the lubricant into a condition-monitoring tool.
Lubricating CO2 (R-744) Refrigeration Systems: Pressure, Solubility and Oil Selection
CO2 is a natural refrigerant with a GWP of 1, but it asks more of the compressor oil than any HFC. Why R-744 is different, what the oil must do in sub...
CO2 is a natural refrigerant with a GWP of 1, but it asks more of the compressor oil than any HFC. Why R-744 is different, what the oil must do in subcritical cascade and booster systems, and where RF POE 85 CO2 fits.
Moisture, Hydrolysis and Acid Control in POE Systems
Polyolester oils make HFC and HFO refrigeration possible, but they absorb water, and water turns esters into acids. The chemistry, the warning signs a...
Polyolester oils make HFC and HFO refrigeration possible, but they absorb water, and water turns esters into acids. The chemistry, the warning signs and a practical handling protocol that keeps POE systems dry.
Viscosity Selection Under Refrigerant Dilution: Why ISO VG Is Only the Starting Point
The viscosity printed on the drum is measured with no refrigerant present. At the bearing, dissolved refrigerant can reduce it dramatically. How to se...
The viscosity printed on the drum is measured with no refrigerant present. At the bearing, dissolved refrigerant can reduce it dramatically. How to select a grade on working viscosity, not label viscosity.
Miscibility and Oil Return: Matching Oil Chemistry to Refrigerant
Oil that does not dissolve in the refrigerant does not come back to the compressor. How mineral, alkylbenzene, POE, PAG and PAO oils behave with HCFC,...
Oil that does not dissolve in the refrigerant does not come back to the compressor. How mineral, alkylbenzene, POE, PAG and PAO oils behave with HCFC, HFC, HFO and CO2 refrigerants, and how to read a miscibility table.
Beyond the Drum: Why Compressor Lubrication Is an Engineering Decision
In a refrigeration compressor the oil lubricates, seals, cools and travels the whole circuit with the refrigerant. Choosing it is an engineering decis...
In a refrigeration compressor the oil lubricates, seals, cools and travels the whole circuit with the refrigerant. Choosing it is an engineering decision, and that is how AA Lubricants approaches every application.